Gas boiler signal 10c instructions. How to choose a Signal gas boiler and install it correctly? Features of domestic boilers Signal

Designed for water heating of residential and office premises, equipped with water heating systems (WHO).

ATTENTION! When purchasing a boiler, ask the trading organization to fill out warranty repair coupons, check the completeness and presentation of the boiler.
After the boiler is sold to the buyer, the manufacturer does not accept claims for incompleteness and mechanical damage.
NOTE. The boiler runs on natural gas.

Water is used as a coolant in accordance with GOST R 51232-98 and SanPiN 2.1.4.1074-01 with a carbonate hardness of no more than 2 mg. eq/l
It is allowed to use a low-freezing liquid instead of water - household antifreeze Нot Вlood, “Dixis”, “Warm House - 65”.

ATTENTION! Installation, commissioning of the boiler and instruction are carried out by gas service specialists, the manufacturer's service department or specialized installation services that have a license (permit) for this type of work, with the obligatory completion of a boiler installation control coupon, signature and seal.

The boiler can be installed in a closed heating system with a membrane-type expansion tank.

NOTE. There may be minor discrepancies between the description and the design of the boiler, which are associated with its constant technical improvement.

MAIN TECHNICAL PARAMETERS

Options Designation
KOV-SG-43
Comfort
KOV-SG-50
Comfort
1 2 3
Boiler efficiency coefficient(during continuous operation), %, not less: 85
Type of gas Natural according to GOST 5542-87
Natural gas pressure, Pa (mm.water column):
- nominal
- minimum/maximum
1274 (130)
635 (65)/1764(180)
Nominal thermal power of burners, W (Kcal/h) 43000 (37000) 50000 (43000)
Heating of premises with heat loss, W, no more
(approximate area of ​​the heated room with a height of H = 2.7 m depending on the climatic conditions of the area, m 2)
37000
300 ÷ 360
43000
350 ÷ 430
Nominal heating capacity,
W (Kcal/hour)
36000 (31000) 43000 (37000)
Gas consumption: natural with a density of 0.73 kg/m 3 at a pressure of 1274 Pa (130 mm water column) m 3 / h. no more 4,7 5,5
Vacuum in the chimney, Pa (mm.water column)
- minimum ⁄ maximum
2,94 (0,3) ⁄ 39,4 (4,0)
Tightness of gas communications, shut-off device, safety valve, thermostat valve. Allowed air leakage, cm 3 /h, no more 70
Ignition time, sec., no more 60
Carbon monoxide content, mg/m 3, no more 119
Content of nitrogen oxides, mg/m 3, no more 260
Range of maintaining water temperature in the heat exchanger, °C 50 ÷ 90
Burner type Injection
Tank capacity, l 58 55
Outer diameter of the connecting pipe of the gas exhaust device, mm 165±2
Connecting thread of fittings for:
- gas supply
- supply and drainage of water to the heating part
G3/4
G2
Water pressure in the heating system, kPa, no more 150
Distance from the floor to the axis of the gas pipeline inlet pipe, mm 235±5
Distance from the floor to the end of the heat exchanger outlet pipe, mm 842±5
Distance from the floor to the axis of the heat exchanger inlet pipe, mm 238±5
Overall dimensions, mm:
height x width x depth
995±5 x 455±5 x 600±5
Boiler weight (without packaging), kg, no more 71 75

SAFETY REQUIREMENTS

ATTENTION! The boiler is maintained by the owner. Installation and initial startup of the boiler must be carried out only by the gas industry, the service department of the manufacturer or specialized installation services that have a special license (permit) for this type of work.

To avoid accidents and damage to the boiler PROHIBITED:

  • . turn on the boiler for persons who have not undergone special training (instruction) and for children;
  • . use fire to detect gas leaks (use soap emulsion for these purposes);
  • . turn on the boiler when there is no draft in the chimney and without first filling the heating system and boiler with water;
  • . press the start button and rotate the water heating thermostat adjustment knob unnecessarily;
  • . adjust the adjustment knob of the thermostat of the automation unit to a water temperature above 90°C;
  • . knock on the burner, automation, turn the handle of the gas tap, the thermostat adjustment knob using keys, pliers and other tools;
  • . place flammable objects (paper, rags, etc.) on the boiler and pipelines;
  • . dry clothes near the boiler and on pipelines;
  • . place flammable substances and materials on the boiler or near it;
  • . use a faulty boiler;
  • . the owner to repair and reinstall the boiler, as well as make any changes to the design.

ATTENTION! The work of installing, connecting and putting into operation the boiler is carried out by the gas industry, service or specialized installation services that have a license (permit) for this type of work, according to a project agreed upon with the operating organization (trust) of the gas industry. The service specialist who starts the gas must instruct the user on the rules for using and maintaining the boiler, making an entry in the control coupon with mandatory confirmation by signature and seal. If these records are missing, the control coupon will be considered invalid and warranty repairs will not be performed.

MAINTENANCE.

Preventive inspection and repair of the boiler is carried out by specialists from the gas industry, the service department of the manufacturer, and a service department that has a license (permit) for this type of work.

Monitoring the operation of the boiler is the responsibility of the owner, who is obliged to keep the boiler clean and in good condition.

To increase the service life of the boiler and economical gas consumption, it is recommended to fill the heating system with clean, chemically non-aggressive water with a carbonate hardness of no more than 2 mg. eq/l

LIST OF MANDATORY PREVENTIVE WORK CARRIED OUT BY THE SERVICE SERVICE

Name of works Frequency of work
1 2
Cleaning the main and ignition burner nozzles, heat exchanger pipes, filter As needed
Checking the tightness of all connections At each maintenance schedule visit
Checking the draft in the chimney and the free rotation of the draft interrupter door As needed, but at least once a year
Dismantling and lubrication of the gas valve in front of the boiler As needed (in case of jamming)
Cleaning the thermocouple from carbon deposits As needed
Checking the functionality of automatic traction and automatic overheating As needed
Checking the operation of the automatic flame safety and thermostat Same
Checking the operation of piezo ignition Same
Cleaning the burner grooves in the upper part of the burner from scale, soot, and condensate salts with a metal brush. After cleaning, blow out the burner with air. Same
Cleaning turbulators from soot As needed. Burning of the lower ends of the turbulators during operation to a length of 50-70 mm does not affect the operation of the product and is not a defect
Replacement of small parts and repairs As needed

WARRANTY

The boiler meets the requirements of GOST R 51733-2001, TU 4931-002-07504413-99.
The warranty period is 24 months from the date of sale, but no more than 36 months from the date of release of the boiler by the manufacturer (12 months - pre-sale storage). In the absence of a stamp from the trading organization, the warranty period (24 months) is calculated from the date of manufacture of the boiler.
The manufacturer guarantees trouble-free operation of the boiler, provided that the consumer follows the rules of operation, care and storage given in this manual.

Warranty boiler repairs are not carried out in the following cases:

  • . failure to comply with safety requirements;
  • . failure to comply with the rules for installing and connecting the boiler;
  • . failure to comply with the rules of operation, maintenance, repair and care of the boiler;
  • . negligence of storage, handling, transportation of the boiler by the owner or trading organization;
  • . as well as for other reasons beyond the control of the manufacturer.

Gas boiler Signal - single- and double-circuit floor-standing models

5 (100%) votes: 3

Currently, the manufacturer of heating equipment, LLC Signal-Teplotekhnika, stands out among competitors on the Russian market, which is integral part Signal company. This manufacturer produces both industrial and household gas boilers. In this article we will look at the distinctive features of this equipment.

Gas boiler "Signal" today

The company was founded in 1951 and initially its main activity was the production of precision instruments for aviation and space purposes.

You can find out the price and buy heating equipment and related products from us. Write, call and come to one of the stores in your city. Delivery throughout the Russian Federation and CIS countries.

In 1991, they began producing gas industrial and domestic boilers. Products manufactured by Signal can be divided into three categories:

  1. Gas heating boilers, which are designed to supply heat to residential and industrial premises.
  2. Measuring instruments.
  3. Gas control automation.

The following equipment is offered for heating houses and other residential premises:

  • double-circuit floor-standing gas boiler;
  • single-circuit floor-standing gas boiler;
  • universal stoves for baths and saunas.

All heating gas boilers "Signal" are made in accordance with international quality standards and have the ISO 9001:2001 standard. In addition, the products have passed federal certification and comply with GOST R ISO 9001-2001; RV 15 002-2003.

Dual circuit power gas boiler, produced by the described manufacturer, varies from 10 to 40 kW. Therefore, such heating devices are suitable for heating small houses, and larger areas (up to 350 m²).

Specifications

Gas boilers "Signal" are used to supply heat and hot water industrial premises and private houses. The devices are characterized by: high performance, safety, as well as ease of use and efficiency.

Other advantages include:

  1. Very attractive pricing policy. When compared with other domestic manufacturers producing similar products, Signal equipment is cheaper.
  2. Thanks to the automation included with the Signal gas boiler, it is absolutely safe to operate.
  3. Its operation is stable and reliable.
  4. Thanks to the modern design, the boilers look attractive in appearance.
  5. The Signal gas boiler has piezo ignition, which allows you to start the unit without using matches.
  6. High efficiency is due to the use of two operating modes of the gas burner. The analogue mode is intended for the normal operation of a gas boiler. In this mode, the burner does not go out and outputs the boiler to 100% of the rated power. In relay mode, gas is saved due to the frequency of burner operation (on-off cycle). In this mode, the unit can produce from 25 to 50% of the rated power.

Models of gas boilers Signal

All Signal boilers intended for domestic use are divided into two series:

  1. Standard;
  2. Comfort (S-TERM).

Standard

This series includes single-circuit/double-circuit boilers, the power of which varies from 6.5 to 100 kW. Reviews from owners of such gas boilers indicate that the equipment is very reliable and, with proper care and compliance with operating rules, will last a long time.

Let's look at the most popular models included in this series.

KOV-ST 7-16 kW.

This gas boiler is equipped with a tubular-type steel heat exchanger.

His specifications:

  • compact size;
  • ergonomic front panel, thanks to which control sensors are conveniently located;
  • modified automatic equipment SIT, BRGG-1EM;
  • traction control sensors, flame presence, built-in thermostat.

Gas boiler Signal KOV 10 ST1ps

Review of heating boiler “Signal” KOV-10ST

KOV-ST 20-100 kW.

This model is characterized by increased power, so they will cope well with heating large areas.
Distinctive features:

  • Barg automation;
  • circulation pump;
  • slot burners;
  • It is possible to connect and .

The model with a rated power of 63 kW is equipped with Italian Honeywell automation, which has a positive effect on reducing gas consumption by 15-20%.

Comfort

This series features the Signal S-TERM boiler. Models with powers of 10 kW, 12.5 kW, 16 kW are available for sale.

HEATING BOILER
WATER HEATING

KOV-ST "SIGNAL"

MANUAL

SYAMI.621261-306 RE8

"Signal"

Introduction 3

1 Description and operation 4

1.1.1 Purpose 4

1.1.2 Technical specifications 5

1.1.3 Completeness 6

1.1.4 Design and operation 6

1.1.5 Operating procedure 10

2 Maintenance 11

2.1 Boiler placement 11

2.2 Installation instructions 12

2.3 Safety precautions 13

2.4 Requirements for the heating system 14

2.5 Requirements for the smoke removal system 14

3 Pack 15

4 Storage 15

5 Transportation 15

6 Disposal 15

7 Manufacturer's warranty 16

8 Certificate of acceptance 17

Control card for boiler installation 18

Warranty card 19

Possible malfunctions and methods for eliminating them 21

Information about the contents of precious

and non-ferrous metals 23

List of organizations producing

This instruction manual contains a description of the design, technical characteristics, principle of operation, rules of installation, maintenance, certificate of acceptance, packaging, storage, manufacturer's warranty and other information necessary for correct

installation and operation of a water heating boiler with a steel pipe heat exchanger KOV-ST, KOV-STPV “Signal” (hereinafter referred to as the boiler).


The manufacturer reserves the right to make changes to the boiler design that do not impair its operation.

Due to constant technical improvement, minor changes in designs and functional solutions are possible.

When purchasing a boiler, check its completeness and presentation. After the sale of the boiler, the manufacturer does not accept claims for incompleteness, presentation and mechanical damage.

Require the trading organization to fill out a warranty card.

1 DESCRIPTION AND OPERATION

1.1 Description and operation of the product.

1.1.1 Purpose.

KOV-ST, KOV-STPV boilers are designed for heating houses, cottages and apartments equipped with a water heating system with a working water pressure of up to 0.1 MPa, and the KOV-STPV boiler is also intended for supplying hot water for sanitary needs.

Distinctive features of our boiler are:

Automatic regulation of the boiler heating output in the range from 100% to 25% of the rated heating output in analogue mode (the burner does not go out) and in the range less than 25% in relay mode (burner extinguishing-ignition). This leads to gas savings and ultimately saves you money;

Gas is supplied to the main burners only when there is a flame on the pilot burner;

Stopping the gas supply to the gas burner device in the event of an emergency shutdown of gas, when the water in the heat exchanger overheats, when the flame on the ignition burner goes out, or when the chimney is clogged (draft failure);

The presence of piezo ignition will help you light the burner;

The presence of an ignition indicator will help you control the operation of the ignition burner;

The presence of a relief valve that is triggered when the water pressure in the heating system exceeds.

1.1.2 Technical characteristics 1.1.2.1 Technical data, main parameters and characteristics

are given in table 1.

Table 1

Parameter name

Values ​​of indicators

KOV-10STPV

KOV-12.5STPV

KOV-16STPV

1 Nominal heat output of the boiler, Nnom, kW

2 Gas consumption at rated heating capacity, Q nm3/h:

3Regulation range

heating capacity, % Nnom

From 25 to 100

4 Volume of water held by the boiler, V, l

5 Efficiency factor, η, %, not less

6 Type of fuel

Natural gas according to GOST 5542-87

7 Nominal pressure of natural gas at the inlet to the boiler, Pa.

8 Natural gas pressure range, Pa

9 Working water pressure, Work., in the heating system, MPa, no more

10 Range of regulation of water temperature at the boiler outlet, 0 C

11 Air vacuum range behind the boiler, Pa

12 Temperature of combustion products at the boiler outlet, 0С, not less

13 Connecting thread of pipes for supplying and draining water to the heating system according to GOST 6357-81

14 Chimney diameter, mm

15 Connecting thread

RA for gas supply according to GOST 6357-81

16 Connecting thread of fittings for supplying and discharging sanitary water according to GOST 6357-81

17 Water consumption for sanitary needs, l/min. at ∆t= 35ºС

18 Overall dimensions, mm, no more:

Depth (A)

Width (B)

Height(L)

19 Weight, kg, no more

1.1.3 Completeness


1.1.3.1 The complete set of the boiler is given in table 2

table 2

Note – The operating manual for the gas burner device is sent to regional representatives, representatives of Gorgaz (raygas) and service centers upon their request.

1.1.4 Design and operation

1.1.4.1 The boiler design is shown in Figure 1. Electrical diagram connections - in Figure 2, design of the gas burner device - in Figure 3.

The boiler consists of the following main components: a heat exchanger, a burner, safety sensors for draft and limit temperature, an igniter operation indicator, piezo ignition, a temperature indicator, and the KOV-STPV boiler additionally includes a copper coil.

1.1.4.2 The thermogenerator located in the pilot burner flame, after opening the valve, generates thermoEMF, which is supplied to the electromagnet winding of the inlet valve of the gas valve 2 of the gas burner device.

An electromagnet holds the valve in the open position - gas flows to the ignition and main burners that are part of the gas burner device. On the scale of the gas valve regulator, the temperature value leaving the water boiler is set, according to Table 3.

Table 3

When the set water temperature is reached, the thermostat valve closes and reduces the flow of gas to the main burners, automatically adjusting the heating output.

The draft safety sensor or the maximum temperature safety sensor breaks the power supply circuit of the inlet valve electromagnet when the draft in the furnace is disrupted or the outlet water is heated above 95ºC, respectively, the inlet valve blocks the passage of gas to the main and ignition burners, the burners go out. The thermogenerator cools down and stops producing EMF. The burner is ignited manually after eliminating the reasons that caused the cessation of draft in the firebox or overheating of the outlet water.

1-gas burner device, 2-block gas burner regulator, 3-scale

water temperature regulator, 4-heating water temperature indicator, 5-safety sensor for limit temperature DBPT, 6-sensor

traction safety DBT, 7-terminal block, 8-door, 9-wall

lateral left, 10-pipe with gasket for gas connection,

11-thermal generator TG-4, 12-cold sanitary water supply fitting,

13-pipe for connecting incoming heating water, 14-pipe

connecting the outlet heating water, 15-plug with gasket,

16-knob of the regulator block, 17-indicator of operation of the igniter URZ, 18-button

piezo ignition, 19-pipe connection for the chimney, 20-cap nut,

21-pipe with filter, 25-pipe for hot sanitary water outlet

Note – In the KOV-ST boiler there are no fittings 12 and 25.

Figure 1 – Design of the KOV-STPV boiler

https://pandia.ru/text/80/064/images/image004_69.jpg" width="623" height="623">

1 - gas distributor with plugs, 2 - main burner pipes, 3 - ignition burner, 4 - thermogenerator, 5 - automatic control unit, 6 - front sheet with bushings, 7 - piezo ignition, 8 - pipe with filter

Figure 3 - Design of the gas burner device GGU-BM

1.1.5 Operating procedure

1.1.5.1 Starting the boiler.

The first start-up of the boiler is carried out by the service department when installing the boiler in the following sequence:

2) Remove the door.

3) Check the presence of draft with a draft gauge.

IF THERE IS NO DRAFT, IGNITE THE GAS BURNER

THE DEVICE IS PROHIBITED.

4) Open the gas valve on the gas supply pipeline.

5) Set the thermostat knob to position “1”.

6) Turn the handle of the regulator block counterclockwise to the “IGNITER” position (see Figure 4).

Ventilation" href="/text/category/ventilyatciya/" rel="bookmark">ventilation through openings near the floor and ceiling.

The total area of ​​the opening openings is selected at the rate of 1 cm2 for every 225 W of gas burner device power.

For example, GGU - 12BM - power of the gas burner device - 12 kW.

Then the area of ​​the opening will be:

The room should be spacious enough for unobstructed access to the boiler during maintenance work.

IT IS PROHIBITED TO INSTALL THE BOILER IN A PIT.

2.2 Installation instructions.

2.2.1 Before installation and operation, carefully read the rules and recommendations contained in this manual.

Installation, instruction for operation, commissioning, preventive maintenance and repair of the boiler are carried out by a specialized organization and local gas management in accordance with PB12-529-2003, approved by Rostekhnadzor of the Russian Federation, and building codes and regulations SNiP 41-01-2003 and SP 41 -108-2004 Gosstroy of the Russian Federation with the obligatory completion of a control coupon for boiler installation.

If the rules set out in this manual are violated, the boiler is not subject to warranty repair.

2.2.2 Install through the hole in the side left wall, pos. 9 (see Figure 1), the pipe with the gasket, pos. 10, from the delivery set, into the union nut, pos. 20. Tighten the union nut and connect the boiler to the gas main. Check the tightness of the joints by soaping.

Do not use a flame or spark to detect a gas leak. For this purpose, you can only use soap foam, specially designed liquid formulations or special ones. leak detectors.

Install the relief valve. To do this, unscrew the plug pos. 15 (see Figure 1) and screw in the supplied relief valve with the same gasket that was on the plug, using a standard set of keys.

2.2.3 At the outlet pipe of the heating system for KOV-STPV boilers, install a ball valve with the bore diameter of your system. The tap is necessary to turn off the heating system and ensure the operation of the hot water supply system during unheated periods.

2.2.4 CONNECTIONS OF THE BOILER TO THE HEATING SYSTEM AND GAS MAIN MUST BE THREADED ONLY, ALLOWING THE BOILER TO BE DISCONNECTED.

2.2.5 Horizontal sections of the heating system pipelines must be made with a slope of at least 10 mm per 1 m towards the heating devices (heating radiators) and from the heating devices to the boiler.

2.2.6 When installing the boiler in an unheated room or when pipelines pass through an open space or an unheated room, they must be thoroughly insulated.

2.2.7 The expansion tank is installed at the top point of the riser, preferably in a heated room. When installing a tank in an unheated room, the pipelines, tank and drain pipe must be carefully insulated.

2.2.8 There should be no areas in the heating system where air pockets can form.

2.2.9 Pipelines, heating devices (heating radiators) and joints must be sealed, water leaks are not allowed.

2.3 Safety precautions

2.3.1 Maintenance of the boiler must be carried out by specially trained, qualified personnel.

Availability: in stock

18500 rub.

Purpose

Designed for heating and hot water supply of premises with an area of ​​160 m².

Advantages

  • Italian automation “EuroSit 630”;
  • Italian Polidoro burner (reduced noise level of the boiler);
  • new pilot burner (use of imported pilot burner);
  • a thermocouple is used as a thermoEMF source;
  • use of modern components available in any region of Russia;
  • easy access to the elements of the gas burner device for maintenance and repair;
  • modern dyeing technology.

Safety

Devices installed on the boiler ensure safe operation in the following cases:

  • violation of cravings or its complete absence;
  • low gas pressure (complete shutdown), as well as extinguishing of the pilot burner;
  • overheating of the coolant.

Specifications:

Parameter nameValues ​​of indicators
Nominal heating output of the boiler, N nom kW 16
Heated area, m² 160
Efficiency, %, not less 90
Average gas consumption, m³/h 0,9
Working water pressure in the heating system, MPa, no more 0,13
Water volume held by the boiler, V, l 23
Heating water temperature control range, °C 50...90
Water consumption for sanitary needs, l/min at Δt=30°С 5,4
Weight, kg 49
Overall dimensions (without packaging) (depth, width, height), mm 470×260×850
Chimney diameter, mm 100
Warranty period 36 months from date of sale. Starting from the 14th month of operation, the warranty is valid only if there is a mark indicating the completion of annual service.
Service life, years, not less 15

Production: EPO Signal LLC, Engels

Operating instructions for the KOV-16SKVS boiler:

http://signal-teplo.ru/upload/%D0%A0%D1%83%D0%BA%D0%BE%D0%B2%D0%BE%D0%B4%D1%81%D1%82%D0 %B2%D0%BE%20%D0%BF%D0%BE%20%D1%8D%D0%BA%D1%81%D0%BF%D0%BB%D1%83%D0%B0%D1%82 %D0%B0%D1%86%D0%B8%D0%B8%20(%D0%9A%D0%9E%D0%92-7%20-%20%2025%D0%A1%D0%9A(% D0%92)%D0%A1%20).pdf

We offer to buy a floor-standing double-circuit gas heating boiler KOV-16SKVs to provide heat supply and hot water supply in private country houses or apartments, as well as in organizations performing communal functions. In other words, in almost any buildings and premises equipped with water heating systems with natural circulation.

Floor-standing double-circuit gas boilers for home heating KOV-16SKVs are a type of non-volatile device equipped with a built-in atmospheric burner, which significantly increases the reliability of the boiler and its efficiency. And the increased quality of the technical level of assembly of the device allows it the best way manifest itself in places where the power supply system faces frequent interruptions. This floor-standing double-circuit gas boiler will be especially useful for heating and hot water supply to a private home - its operation does not require electricity, the water in the pipeline is heated automatically. Inside, the boiler is divided using special water sections with embedded economizers. Thus, the use of thermal energy from gas combustion will be as efficient as possible and practically waste-free.

The price of the Russian floor-mounted double-circuit gas heating boiler KOV-16SKVs continues to remain very low. The maximum water temperature at the outlet of the boiler is 90 o C, the maximum liquid pressure is no more than 0.13 MPa. For operation of the device, ordinary gaseous fuel is required - either natural gas (GOST 5542) with a nominal pressure of 1.3 kPa, or liquefied gas (GOST 20448) nominal pressure 3.0 kPa. If you require modern, high quality home heating equipment manufactured to the highest fire and safety standards environmental safety, as well as consuming a minimum amount of fuel and independent of the presence or absence of an electrical network in the premises, then you can safely buy a double-circuit gas boiler for a private house KOV-16SKVs right now.

One of the leaders among domestic manufacturers of heating gas equipment is Signal-Teplotekhnika LLC, part of the Signal group of companies. This industrial group works in the field of gas equipment, producing household and commercial models.

Since its founding in 1951, the company until 1990 was the largest manufacturer of precision instruments for aviation and space applications. With changes in market conditions, the company changes the direction of its activities and retrains to produce gas equipment.

"Signal" today

Since 1991, the company has been establishing serial production of gas equipment for domestic and industrial use. The signal plant is the largest in the Saratov region. Today its products can be divided into three categories:

  1. Gas equipment for heating residential and industrial premises.
  2. Measuring instruments.
  3. Automatic gas control.

For domestic purposes (heating houses and other residential premises), the signal company offers the following equipment:

  • Double-circuit floor-standing boiler.
  • Floor-standing single-circuit boiler with increased power (up to 100 kW).
  • Universal stoves for saunas and baths.

In addition to household heating appliances, the signal company produces and supplies transportable water heating and boiler units with a capacity of up to 100 MW.


Among the company's achievements it is worth noting:

  1. Victory at the competition of regional manufacturers “Saratov Brand - 2008”.
  2. Industry Leader Award in 2010.
  3. Official gratitude from the President of Russia in 2011.

In addition, it is worth noting that the products of the Engel plant signal correspond to international standards quality and has ISO 9001:2001 standard. Also, the company’s products have passed federal certification and comply with GOST:

  1. R ISO 9001-2001;
  2. RV 15 002-2003.

In the group of companies, Signal has formed a full production cycle. Any gas boiler is completely manufactured and assembled at our own production facilities.

Advice! The signal brand double-circuit gas boiler has a rated power of 10 to 40 kW and is optimally suited for heating both a small dacha and a cottage with an area of ​​up to 350 sq. m.

Features of domestic boilers Signal

The signal heating boiler is suitable for heating and hot water supply of industrial premises and private houses of various sizes. High efficiency and high safety make the operation of this equipment convenient and economical.


All products are certified and have the following advantages:

  • Pleasant pricing policy. Compared to other Russian manufacturers of heating systems, the signal boiler has a lower price.
  • High degree of safety of gas equipment. Our own production of monitoring automation allows us to ensure the reliability, safety and stability of the boiler.
  • Modern design and comfortable operation. Built-in piezo ignition allows you to quickly start a gas boiler without using matches.

It is also worth noting the high efficiency, which is achieved by using two operating modes of the gas burner:

  1. The analogue mode is intended for normal boiler operation. In this mode, the burner does not go out and outputs the boiler to 100% of the rated power.
  2. Relay mode implies significant gas savings due to the frequency of burner operation (on-off cycle). In this mode, the boiler is capable of delivering from 25 to 50% of the rated power.

The lineup

All household heating devices signal are divided into two series:

Standard series

This series includes floor-standing boilers of single- and double-circuit design with a power from 6.5 to 100 kW. The reliability and durability of such a device is confirmed by numerous consumer reviews.

Let's look at a few of the most popular models from this line. KOV-ST 7-16 kW boilers have a tubular-type steel heat exchanger. Main technical characteristics of such a boiler:

  • The ergonomic front panel allows for convenient placement of control sensors.
  • Compact dimensions.
  • Modified automatic SIT, BRGG-1EM.
  • Sensors for traction control, flame presence, built-in thermostat.

Gas boilers KOV-ST 20-100 kW are distinguished by increased power, suitable for heating large areas. Features of the device of this line:

  • Automation Barg.
  • Slot burners.
  • Circulation pump.
  • Possibility of connecting a gas alarm and an electronic programmer.

Advice! In models with a nominal power of 63 kW, Italian Honeywell automation is installed. This makes it possible to reduce gas consumption by approximately 15–20%.

Comfort series

The comfort series includes the S-TERM signal boiler. These gas devices are available in three capacities: 10; 12.5 and 16 kW. The main technical characteristics and design features are as follows:

  • The used analogue of the Italian Polidoro burner allows us to achieve a significant reduction in noise during boiler operation.
  • High efficiency of at least 90%.
  • Modern pilot burner.
  • Built-in thermocouple.
  • Automation Eurosit 630.

The safety of operation of this heating equipment is ensured by the following sensors:


  • gas pressure;
  • control of the flame on the burner;
  • traction sensor;
  • The built-in thermostat signals overheating of the coolant.

This floor-standing double-circuit boiler of the signal brand allows you to achieve maximum comfort, providing uninterrupted heat and hot water supply. The products of the domestic manufacturer of gas boilers - the signal brand - are in demand among consumers due to the low price of reliable, safe and durable heating equipment. The use of our own developments and the experience of foreign colleagues makes the Signal company a leader in sales volumes.